Datasheet
M24M01-R M24M01-DF DC and AC parameters
Doc ID 12943 Rev 10 27/38
Table 13. DC characteristics (M24M01-F, device grade 6)
Symbol Parameter
Test conditions (in addition to
those in Tab l e 6)
Min. Max. Unit
I
LI
Input leakage current
(E1, E2, SCL, SDA)
V
IN
= V
SS
or
V
CC
device in Standby mode
± 2 µA
I
LO
Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: V
SS
or
V
CC
± 2 µA
I
CC
Supply current (Read)
V
CC
= 1.7 V, f
c
= 400 kHz 1 mA
V
CC
= 2.5 V, f
c
=400 kHz 1 mA
V
CC
= 5.5 V, f
c
=400 kHz 1.5 mA
f
c
= 1 MHz 1.5 mA
I
CC0
Supply current (Write) During t
W
2
(1)
1. Characterized only, not tested in production.
mA
I
CC1
Standby supply current
Device not selected,
V
IN
= V
SS
or
V
CC
, V
CC
= 1.7 V
3µA
Device not selected,
V
IN
= V
SS
or
V
CC
, V
CC
= 2.5 V
3µA
Device not selected,
V
IN
= V
SS
or
V
CC
, V
CC
= 5.5 V
5µA
V
IL
Input low voltage
(SCL, SDA, WC)
1.7 V ≤ V
CC
< 2.5 V –0.45 0.25 V
CC
V
2.5 V ≤ V
CC
< 5.5 V –0.45 0.30 V
CC
V
V
IH
Input high voltage
(SCL, SDA)
1.7 V ≤ V
CC
< 2.5 V 0.75 V
CC
V
CC
+1 v
2.5 V ≤ V
CC
< 5.5 V 0.70 V
CC
0 V
CC
+1 v
V
OL
Output low voltage
I
OL
= 1.0 mA, V
CC
= 1.7 V 0.2 V
I
OL
= 2.1 mA, V
CC
= 2.5 V 0.4 V
I
OL
= 3.0 mA, V
CC
= 5.5 V 0.4 V