Datasheet

DC and AC parameters M24M01-R M24M01-DF
24/38 Doc ID 12943 Rev 10
8 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Figure 11. AC measurement I/O waveform
Table 6. Operating conditions (voltage range R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1 MHz
Table 7. Operating conditions (voltage range F)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1 MHz
Table 8. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
bus
Load capacitance 100 pF
SCL input rise/fall time, SDA input fall time - 50 ns
Input levels 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference levels 0.3 V
CC
to 0.7 V
CC
V
Table 9. Input parameters
Symbol Parameter
(1)
1. Sampled only, not 100% tested.
Test condition Min. Max. Unit
C
IN
Input capacitance (SDA) 8 pF
C
IN
Input capacitance (other pins) 6 pF
Z
L
Input impedance (WC)
V
IN
< 0.3 V
CC
30 kΩ
Z
H
V
IN
> 0.7 V
CC
400 kΩ
-36
6
##
6
##
6
##
6
##
)NPUTANDOUTPUT
4IMINGREFERENCELEVELS
)NPUTVOLTAGELEVELS