Datasheet

DocID16891 Rev 28 23/42
M24C64-W M24C64-R M24C64-F
41
8 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Operating conditions (voltage range W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1
(1)
1. f
Cmax
is 1 MHz devices identified by process letter K.
MHz
Table 7. Operating conditions (voltage range R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1
(1)
1. f
Cmax
is 1 MHz devices identified by process letter K.
MHz
Table 8. Operating conditions (voltage range F)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1
(1)
1. f
Cmax
is 1 MHz devices identified by process letter K.
MHz