Datasheet
DC and AC parameters M24C32-W M24C32-R M24C32-F M24C32-X M24C32-DF
24/40 Doc ID 4578 Rev 21
8 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Operating conditions (voltage range W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1 MHz
Table 7. Operating conditions (voltage range R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1 MHz
Table 8. Operating conditions (voltage range F)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1 MHz
Table 9. Operating conditions (voltage range X)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.6 5.5 V
T
A
Ambient operating temperature –20 85 °C
f
C
Operating clock frequency - 1 MHz
Table 10. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
bus
Load capacitance 100 pF
SCL input rise/fall time, SDA input fall time 50 ns
Input levels 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference levels 0.3 V
CC
to 0.7 V
CC
V