Datasheet
DocID023494 Rev 4 21/38
M24C16-W M24C16-R M24C16-F DC and AC parameters
37
8 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 5. Operating conditions (voltage range W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 400 kHz
Table 6. Operating conditions (voltage range R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 400 kHz
Table 7. Operating conditions (voltage range F,
for devices identified by process letter T)
Symbol Parameter Min. Max. U
nit
V
CC
Supply voltage 1.60 1.65 1.70 5.5 V
T
A
Ambient operating temperature: READ -40 -40 -40 85
°C
Ambient operating temperature: WRITE 0 -20 -40 85
f
C
Operating clock frequency - - - 400 kHz
Table 8. Operating conditions (voltage range F, for all other devices)
Symbol Parameter Min. Max. U
nit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature -20 85 °C
f
C
Operating clock frequency - 400 kHz
Table 9. Operating conditions (voltage range F)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7
(1)
1. For devices identified by process letter T: 1.6 for Read, 1.7 for Write.
5.5 V
T
A
Ambient operating temperature –40
(2)
2. –20°C for devices identified by process letters G or S.
85 °C
f
C
Operating clock frequency - 400 kHz