Datasheet

Table Of Contents
DocID023924 Rev 3 25/40
M24C08-W M24C08-R M24C08-F DC and AC parameters
39
Table 14. DC characteristics (M24C08-R, device grade 6)
Symbol Parameter
Test conditions
(1)
(in addition to
those in Table 6 and Table 9)
1. If the application uses the voltage range R device with 2.5 V V
cc
5.5 V and -40 °C < T
A
< +85 °C, please
refer to Table 13 instead of this table.
Min. Max. Unit
I
LI
Input leakage current
(Ei , SCL, SDA)
V
IN
= V
SS
or
V
CC
, device in
Standby mode
2µA
I
LO
Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: V
SS
or
V
CC
2µA
I
CC
Supply current (Read) V
CC
= 1.8 V, f
c
= 400 kHz - 0.8 mA
I
CC0
Supply current (Write)
Value overaged over t
W
,
V
CC
2.5 V
-1
(2)
2. Characterized only (not tested in production) for devices identified by process letter T. I
CC0(max)
is lower
than 0.5 mA when writing data with an ambient temperature greater than 25 °C.
mA
I
CC1
Standby supply current
Device not selected
(3)
,
V
IN
= V
SS
or
V
CC
, V
CC
= 1.8 V
3. The device is not selected after power-up, after a Read instruction (after the Stop condition), or after the
completion of the internal write cycle t
W
(t
W
is triggered by the correct decoding of a Write instruction).
-1µA
V
IL
Input low voltage
(SCL, SDA, WC)
2.5 V V
CC
–0.45 0.3 V
CC
V
V
CC
< 2.5 V –0.45 0.25 V
CC
V
V
IH
Input high voltage
(SCL, SDA)
V
CC
< 2.5 V 0.75 V
CC
6.5 V
Input high voltage
(WC
)
V
CC
< 2.5 V 0.75 V
CC
V
CC
+ 0.6 V
V
OL
Output low voltage I
OL
= 0.7 mA, V
CC
= 1.8 V - 0.2 V