DC and AC parameters M24C04-W M24C04-R M24C04-F
24/34 DocID023994 Rev 3
Table 15. DC characteristics (M24C04-F device, grade 6 and grade 5)
Symbol Parameter
Test conditions
(1)
(in addition to
those in Table 7, Table 8 and
Table 9)
1. If the application uses the voltage range F device with 2.5 V V
cc
5.5 V, please refer to Table 13 instead
of this table.
Min. Max. Unit
I
LI
Input leakage current
(E2,E1, SCL, SDA)
V
IN
= V
SS
or
V
CC
, device in
Standby mode
2µA
I
LO
Output leakage current V
OUT
= V
SS
or
V
CC,
SDA in Hi-Z - ± 2 µA
I
CC
Supply current (Read)
V
CC
= 1.6 V
(2)
or 1.7 V,
f
c
= 400 kHz
2. 1.6 V for devices identified by process letter T.
-0.8mA
I
CC0
Supply current (Write) During t
W
, V
CC
1.8 V - 0.5
(3)
3. For devices identified by process letter T, value averaged over t
W
, characterized only (not tested in
production).
mA
I
CC1
Standby supply current
Device not selected
(4)
,
V
IN
= V
SS
or
V
CC
, V
CC
1.8 V
4. The device is not selected after power-up, after a Read instruction (after the Stop condition), or after the
completion of the internal write cycle t
W
(t
W
is triggered by the correct decoding of a Write instruction).
-1µA
V
IL
Input low voltage
(SCL, SDA, WC)
2.5 V V
CC
–0.45 0.3 V
CC
V
V
CC
< 2.5 V –0.45 0.25 V
CC
V
V
IH
Input high voltage
(SCL, SDA, WC)
-0.7 V
CC
V
CC
+ 1 V
V
OL
Output low voltage I
OL
= 0.7 mA, V
CC
1.8 V - 0.2 V