Datasheet

Table Of Contents
DC and AC parameters M24C04-W M24C04-R M24C04-F
20/34 DocID023994 Rev 3
8 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 5. Operating conditions (voltage range W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 400 kHz
Table 6. Operating conditions (voltage range R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 400 kHz
Table 7. Operating conditions (voltage range F,
for devices identified by process letter T)
Symbol Parameter Min. Max. U
nit
V
CC
Supply voltage 1.60 1.65 1.70 5.5 V
T
A
Ambient operating temperature: READ -40 -40 -40 85
°C
Ambient operating temperature: WRITE 0 -20 -40 85
f
C
Operating clock frequency - - - 400 kHz
Table 8. Operating conditions (voltage range F, for all other devices)
Symbol Parameter Min. Max. U
nit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature -20 85 °C
f
C
Operating clock frequency - 400 kHz
Table 9. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
bus
Load capacitance 100 pF
SCL input rise/fall time, SDA input fall time - 50 ns
Input levels 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference levels 0.3 V
CC
to 0.7 V
CC
V