Datasheet

17/28
M24C16, M24C08, M24C04, M24C02, M24C01
Table 9. DC Characteristics (M24Cxx-W, Device Grade 3)
Note: 1. The voltage source driving only E0, E1 and E2 inputs must provide an impedance of less than 1kOhm.
Table 10. DC Characteristics (M24Cxx-R)
Note: 1. The voltage source driving only E0, E1 and E2 inputs must provide an impedance of less than 1kOhm.
Table 11. AC Measurement Conditions
Symbol Parameter
Test Condition
(in addition to those in Table 6.)
Min. Max. Unit
I
LI
Input Leakage Current
(SCL, SDA, E0, E1,and E2)
V
IN
= V
SS
or
V
CC
± 2 µA
I
LO
Output Leakage Current
V
OUT
= V
SS
or
V
CC,
SDA in Hi-Z
± 2 µA
I
CC
Supply Current
V
CC
=5V, f
C
=400kHz (rise/fall time < 30ns)
3mA
V
CC
=2.5V, f
C
=400kHz
(rise/fall time < 30ns)
3mA
I
CC1
Stand-by Supply Current
V
IN
= V
SS
or
V
CC
, V
CC
= 5 V
A
V
IN
= V
SS
or
V
CC
, V
CC
= 2.5 V
A
V
IL
Input Low Voltage
(1)
–0.45
0.3V
CC
V
V
IH
Input High Voltage
(1)
0.7V
CC
V
CC
+1
V
V
OL
Output Low Voltage
I
OL
= 2.1mA when V
CC
= 2.5V or
I
OL
= 3mA when V
CC
= 5.5V
0.4 V
Symbol Parameter
Test Condition
(in addition to those in Table 7.)
Min. Max. Unit
I
LI
Input Leakage Current
(SCL, SDA, E0, E1,and E2)
V
IN
= V
SS
or
V
CC
± 2 µA
I
LO
Output Leakage Current
V
OUT
= V
SS
or
V
CC,
SDA in Hi-Z
± 2 µA
I
CC
Supply Current
V
CC
=1.8V, f
c
=400kHz (rise/fall time < 30ns)
0.8 mA
I
CC1
Stand-by Supply Current
V
IN
= V
SS
or
V
CC
, 1.8V < V
CC
< 5.5V
A
V
IL
Input Low Voltage
(1)
2.5 V V
CC
–0.45
0.3 V
CC
V
1.8 V V
CC
< 2.5 V
–0.45
0.25 V
CC
V
V
IH
Input High Voltage
(1)
0.7V
CC
V
CC
+1
V
V
OL
Output Low Voltage
I
OL
= 0.7 mA, V
CC
= 1.8 V
0.2 V
Symbol Parameter Min. Max. Unit
C
L
Load Capacitance 100 pF
Input Rise and Fall Times 50 ns
Input Levels
0.2V
CC
to 0.8V
CC
V
Input and Output Timing Reference Levels
0.3V
CC
to 0.7V
CC
V