DC and AC parameters M24C01/02-W M24C01/02-R M24C02-F
22/34 DocID024020 Rev 2
Table 13. DC characteristics (M24C01/02-W, device grade 6)
Symbol Parameter
Test conditions (in addition to those
in Table 5 and Table 9)
Min. Max. Unit
I
LI
Input leakage current
(SCL, SDA, E2, E1)
V
IN
= V
SS
or
V
CC
, device in Standby
mode
2µA
I
LO
Output leakage
current
SDA in Hi-Z, external voltage applied
on SDA: V
SS
or
V
CC
2µA
I
CC
Supply current (Read)
V
CC
= 5.5 V, f
c
= 400 kHz - 1
(1)
1. 2 mA for devices identified by process letter G or S.
mA
V
CC
= 2.5 V, f
c
= 400 kHz - 1 mA
I
CC0
Supply current (Write) During t
W
, 2.5 V V
CC
5.5 V - 0.5
(2)
2. For devices identified by process letter T, value averaged over t
W
, characterized only (not tested in
production).
mA
I
CC1
Standby supply
current
Device not selected
(3)
,
V
IN
= V
SS
or
V
CC
, V
CC
= 2.5 V
3. The device is not selected after power-up, after a Read instruction (after the Stop condition), or after the
completion of the internal write cycle t
W
(t
W
is triggered by the correct decoding of a Write instruction).
-2
(4)
4. 1 µA for previous devices identified by process letters G or S.
µA
Device not selected
(3)
,
V
IN
= V
SS
or
V
CC
, V
CC
= 5.5 V
-3
(4)
µA
V
IL
Input low voltage
(SCL, SDA, WC
)
- –0.45 0.3 V
CC
V
V
IH
Input high voltage
(SCL, SDA, WC)
-0.7 V
CC
V
CC
+1 V
V
OL
Output low voltage
I
OL
= 2.1 mA, V
CC
= 2.5 V or
I
OL
= 3 mA, V
CC
= 5.5 V
-0.4V