Datasheet
Table Of Contents
- 1 Description
- 2 Signal description
- 3 Memory organization
- 4 Device operation
- 5 Instructions
- 6 Initial delivery state
- 7 Maximum rating
- 8 DC and AC parameters
- Table 5. Operating conditions (voltage range W)
- Table 6. Operating conditions (voltage range R)
- Table 7. Operating conditions (voltage range F, for devices identified by process letter T)
- Table 8. Operating conditions (voltage range F, for all other devices)
- Table 9. AC measurement conditions
- Figure 9. AC measurement I/O waveform
- Table 10. Input parameters
- Table 11. Cycling performance
- Table 12. Memory cell data retention
- Table 13. DC characteristics (M24C01/02-W, device grade 6)
- Table 14. DC characteristics (M24C01/02-R, device grade 6)
- Table 15. DC characteristics (M24C02-F, device grade 6)
- Table 16. 400 kHz AC characteristics
- Table 17. 100 kHz AC characteristics (I2C Standard mode)
- Figure 10. Maximum Rbus value versus bus parasitic capacitance (Cbus) for an I2C bus at maximum frequency fC = 400 kHz
- Figure 11. AC waveforms
- 9 Package mechanical data
- Figure 12. TSSOP8 – 8-lead thin shrink small outline, package outline
- Table 18. TSSOP8 – 8-lead thin shrink small outline, package mechanical data
- Figure 13. SO8N – 8-lead plastic small outline, 150 mils body width, package outline
- Table 19. SO8N – 8-lead plastic small outline, 150 mils body width, package data
- Figure 14. PDIP8 – 8-pin plastic DIP, 0.25 mm lead frame, package outline
- Table 20. PDIP8 – 8-pin plastic DIP, 0.25 mm lead frame, package mechanical data
- Figure 15. UFDFPN8 (MLP8) – package outline (UFDFPN: Ultra thin Fine pitch Dual Flat Package, No lead)
- Table 21. UFDFPN8 (MLP8) – package dimensions (UFDFPN: Ultra thin Fine pitch Dual Flat Package, No lead)
- 10 Part numbering
- 11 Revision history

DocID024020 Rev 2 17/34
M24C01/02-W M24C01/02-R M24C02-F Instructions
33
5.2 Read operations
Read operations are performed independently of the state of the Write Control (WC) signal.
After the successful completion of a Read operation, the device internal address counter is
incremented by one, to point to the next byte address.
For the Read instructions, after each byte read (data out), the device waits for an
acknowledgment (data in) during the 9th bit time. If the bus master does not acknowledge
during this 9th time, the device terminates the data transfer and switches to its Standby
mode.
Figure 8. Read mode sequences
Start
Dev select * Byte address
Start
Dev select Data out 1
AI01942b
Data out N
Stop
Start
Current
Address
Read
Dev select Data out
Random
Address
Read
Stop
Start
Dev select * Data out
Sequential
Current
Read
Stop
Data out N
Start
Dev select * Byte address
Sequential
Random
Read
Start
Dev select * Data out 1
Stop
ACK
R/W
NO ACK
ACK
R/W
ACK
ACK
R/W
ACK ACK ACK NO ACK
R/W
NO ACK
ACK ACK
R/W
ACK ACK
R/W
ACK NO ACK