Datasheet

M24512
16/24
Table 14. AC Characteristics (M24512 – W)
Note: 1. For a reSTART condition, or following a Write cycle.
2. Sampled only, not 100% tested.
3. To avoid spurious START and STOP conditions, a minimum delay is placed between SCL=1 and the falling or rising edge of SDA.
4. For M24512 devices whose package marking shows the process letter “A” t
W
(max) = 5ms whereas for M24512 devices whose
package marking shows the process letter “V” t
W
(max) = 10ms
Table 15. AC Characteristics
(1)
(M24512 – R)
Note: 1. The information contained in Table 15. is related to the new M24512 (process letter “A”) and is subject to change without previous
notice.
2. For a reSTART condition, or following a Write cycle.
3. Sampled only, not 100% tested.
4. To avoid spurious START and STOP conditions, a minimum delay is placed between SCL=1 and the falling or rising edge of SDA.
Symbol Alt. Parameter Min. Max. Unit
f
C
f
SCL
Clock Frequency 400 kHz
t
CHCL
t
HIGH
Clock Pulse Width High 600 ns
t
CLCH
t
LOW
Clock Pulse Width Low 1300 ns
t
CH1CH2
t
R
Clock Rise Time 300 ns
t
CL1CL2
t
F
Clock Fall Time 300 ns
t
DH1DH2
(2)
t
R
SDA Rise Time 20 300 ns
t
DL1DL2
(2)
t
F
SDA Fall Time 20 300 ns
t
DXCX
t
SU:DAT
Data In Set Up Time 100 ns
t
CLDX
t
HD:DAT
Data In Hold Time 0 ns
t
CLQX
t
DH
Data Out Hold Time 200 ns
t
CLQV
(3)
t
AA
Clock Low to Next Data Valid (Access Time) 200 900 ns
t
CHDX
(1)
t
SU:STA
Start Condition Set Up Time 600 ns
t
DLCL
t
HD:STA
Start Condition Hold Time 600 ns
t
CHDH
t
SU:STO
Stop Condition Set Up Time 600 ns
t
DHDL
t
BUF
Time between Stop Condition and Next Start Condition 1300 ns
t
W
t
WR
Write Time
5 or 10
(4)
ms
Symbol Alt. Parameter Min. Max. Unit
f
C
f
SCL
Clock Frequency 400 kHz
t
CHCL
t
HIGH
Clock Pulse Width High 600 ns
t
CLCH
t
LOW
Clock Pulse Width Low 1300 ns
t
DL1DL2
(3)
t
F
SDA Fall Time 20 300 ns
t
DXCX
t
SU:DAT
Data In Set Up Time 100 ns
t
CLDX
t
HD:DAT
Data In Hold Time 0 ns
t
CLQX
t
DH
Data Out Hold Time 200 ns
t
CLQV
(4)
t
AA
Clock Low to Next Data Valid (Access Time) 200 900 ns
t
CHDX
(2)
t
SU:STA
Start Condition Set Up Time 600 ns
t
DLCL
t
HD:STA
Start Condition Hold Time 600 ns
t
CHDH
t
SU:STO
Stop Condition Set Up Time 600 ns
t
DHDL
t
BUF
Time between Stop Condition and Next Start Condition 1300 ns
t
W
t
WR
Write Time 10 ms