Datasheet

DC and AC parameters M24512-W M24512-R M24512-DR M24512-DF
24/40 Doc ID 16459 Rev 26
8 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Operating conditions (voltage range W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1
(1)
1. For devices identified by process letter K.
MHz
Table 7. Operating conditions (voltage range R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1
(1)
1. For devices identified by process letter K.
MHz
Table 8. Operating conditions (voltage range F)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
f
C
Operating clock frequency - 1
(1)
1. For devices identified by process letter K.
MHz
Table 9. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
bus
Load capacitance 100 pF
SCL input rise/fall time, SDA input fall time - 50 ns
Input levels 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference levels 0.3 V
CC
to 0.7 V
CC
V