Datasheet
DocID16892 Rev 24 25/39
M24128-BW M24128-BR M24128-BF M24128-DF DC and AC parameters
38
Table 13. DC characteristics (M24128-BW, device grade 6)
Symbol Parameter
Test conditions (in addition to those
in Table 6)
Min. Max. Unit
I
LI
Input leakage current
(SCL, SDA, E2, E1,
E0)
V
IN
= V
SS
or
V
CC
, device in Standby
mode
-± 2µA
I
LO
Output leakage
current
SDA in Hi-Z, external voltage applied
on SDA: V
SS
or
V
CC
-± 2µA
I
CC
Supply current (Read)
V
CC
= 2.5 V, f
c
= 400 kHz
(rise/fall time < 50 ns)
-1
(1)
1. 2 mA for previous devices identified by process letter A.
mA
V
CC
= 5.5 V, f
c
= 400 kHz
(rise/fall time < 50 ns)
-2mA
2.5 V < V
CC
< 5.5 V, f
c
= 1 MHz
(2)
(rise/fall time < 50 ns)
2. Only for devices identified by process letter K (devices operating at f
C
max = 1 MHz, see Table 17).
-2.5mA
I
CC0
Supply current (Write)
During t
W
,
2.5 V ≤ V
CC
≤ 5.5 V
-2
(3)(4)
3. Characterized value, not tested in production.
4. 5 mA for previous devices identified by process letter A.
mA
I
CC1
Standby supply
current
Device not selected
(5)
,
V
IN
= V
SS
or
V
CC
, V
CC
= 2.5 V
5. The device is not selected after power-up, after a Read instruction (after the Stop condition), or after the
completion of the internal write cycle t
W
(t
W
is triggered by the correct decoding of a Write instruction).
-2µA
Device not selected
(5)
,
V
IN
= V
SS
or
V
CC
, V
CC
= 5.5 V
-3µA
V
IL
Input low voltage
(SCL, SDA, WC
, E2,
E1, E0)
(6)
6. E
i
inputs should be tied to V
ss
(see Section 2.3).
- –0.45 0.3 V
CC
V
V
IH
Input high voltage
(SCL, SDA)
-0.7 V
CC
6.5 V
Input high voltage
(WC
, E2, E1, E0)
(7)
7. E
i
inputs should be tied to V
cc
(see Section 2.3).
-0.7 V
CC
V
CC
+0.6 V
V
OL
Output low voltage
I
OL
= 2.1 mA, V
CC
= 2.5 V or
I
OL
= 3 mA, V
CC
= 5.5 V
-0.4V