Datasheet

Applications information LM723
16/21
Note: Typical performance
Regulated output voltage....................5 V
Line regulation (
Δ
V
I
= 30 V)...........10 mV
Load regulation (
Δ
I
O
= 2 A)............80 mV
Note: Current limit transistor may be used for shutdown if current limiting is not required.
Typical performance
Regulated output voltage...........................5 V
Line regulation (
Δ
V
I
= 3 V)...................0.5 mV
Load regulation (
Δ
I
O
= 50 mA)............1.5 mV
Figure 24. Positive switching regulator