SCHEMATIC DIAGRAM (1/4 LM139)
ABSOLUTE MAXIMUM RATINGS
OPERATING CONDITIONS (T
amb
= 25°C)
Symbol Parameter Value Unit
V
CC
Supply voltage ±18 or 36 V
V
id
Differential Input Voltage ±36 V
V
i
Input Voltage -0.3 to +36 V
Output Short-circuit to Ground - note
1)
1. Short-circuits from the output to V
CC
+
can cause excessive heating and eventual destruction. The maximum output current is approximately 20mA
independent of the magnitude of V
CC
+
.
Infinite
p
d
Power Dissipation
2)
DIP14
SO14
TSSOP14
2. Pd is calculated with T
amb
= +25°C, T
j
= +150°C and R
thja
= 80°C/W for DIP14 package
= 150°C/W for SO14 package
= 175°C/W for TSSOP14 package
1500
830
710
mW
T
stg
Storage Temperature Range -65 to +150 °C
T
j
Junction Temperature +150
°C
Symbol Parameter Value Unit
V
CC
Supply Voltage
2 to 32
±1 to ±16
V
Vicm Common Mode Input Voltage Range
0 to (V
CC
+
- 1.5)
V
T
oper
Operating Free-air Temperature Range LM139, LM139A
LM239, LM239A
LM339, LM339A
-55, +125
-40, +105
0, +70
°C
Non-inverting
Input
Inverting
Input
3.5
µ
A
CC
V
CC
V
O
V
3.5
µ
A 100
µ
A
100
µ