Datasheet

Absolute maximum ratings and operating conditions LM139, LM239, LM339
4/19 Doc ID 2159 Rev 3
Table 2. Operating conditions (T
amb
= 25° C)
Symbol Parameter Value Unit
V
CC
Supply voltage
2 to 32
±1 to ±16
V
V
ICM
Common mode input voltage range 0 to (V
CC
+
- 1.5) V
T
oper
Operating free-air temperature range
LM139, LM139A
LM239, LM239A
LM339, LM339A
-55, +125
-40, +105
0, +70
°C