Datasheet
DocID13159 Rev 4 5/26
LD39150 Typical application circuits
26
3 Typical application circuits
(C
I
and C
O
capacitors must be placed as close as possible to the IC pins)
Note: Inhibit pin is not internally pulled down/up then it must not be left floating. Disable the device
when connected to GND or to a positive voltage less than 0.3 V.
Note: Set R2 as close as possible to 4.7 k
Ω
Figure 3. LD39150 fixed version with inhibit
Figure 4. LD39150 adjustable version
V
O
= V
REF
(1 + R
1
/R
2
)