Datasheet
Table Of Contents
- 1 Diagram
- 2 Pin configuration
- 3 Maximum ratings
- 4 Schematic application
- 5 Electrical characteristics
- Table 3. Electrical characteristics of LD1117#12
- Table 4. Electrical characteristics of LD1117#18
- Table 5. Electrical characteristics of LD1117#25
- Table 6. Electrical characteristics of LD1117#33
- Table 7. Electrical characteristics of LD1117#50
- Table 8. Electrical characteristics of LD1117 (adjustable)
- Table 9. Electrical characteristics of LD1117#12C
- Table 10. Electrical characteristics of LD1117#18C
- Table 11. Electrical characteristics of LD1117#25C
- Table 12. Electrical characteristics of LD1117#33C
- Table 13. Electrical characteristics of LD1117#50C
- Table 14. Electrical characteristics of LD1117C (adjustable)
- 6 Typical application
- 7 LD1117 adjustable: application note
- 8 Package mechanical data
- Table 15. TO-220 mechanical data (type STD-ST Dual Gauge)
- Figure 12. Drawing dimension TO-220 (type STD-ST Dual Gauge)
- Table 16. TO-220 mechanical data (type STD-ST Single Gauge)
- Figure 13. Drawing dimension TO-220 (type STD-ST Single Gauge)
- Table 17. SOT-223 mechanical data
- Figure 14. Drawing dimension SOT-223
- Table 18. SO-8 mechanical data
- Figure 15. Drawing dimension SO-8
- Table 19. DPAK mechanical data
- Figure 16. Drawing dimension DPAK (type STD-ST)
- Figure 17. Drawing dimension DPAK (type Fujitsu-subcon.)
- Figure 18. Drawing dimension DPAK (type IDS-subcon.)
- Table 20. Footprint data
- Figure 19. DPAK footprint recommended data
- 9 Packaging mechanical data
- Figure 20. Drawing dimension tube for TO-220 Dual Gauge (mm.)
- Figure 21. Drawing dimension tube for TO-220 Single Gauge (mm.)
- Table 21. SOT-223 tape and reel mechanical data
- Figure 22. Tape for SOT-223 (dimensions are in mm)
- Figure 23. Reel for SOT-223 (dimensions are in mm)
- Table 22. SO-8 tape and reel mechanical data
- Figure 24. SO-8 tape and reel dimensions
- Table 23. DPAK tape and reel mechanical data
- Figure 25. DPAK footprint
- Figure 26. Tape for DPAK
- Figure 27. Reel for DPAK
- 10 Order codes
- 11 Revision history

DocID2572 Rev 33 25/44
LD1117 Package mechanical data
8 Package mechanical data
In order to meet environmental requirements, ST offers these devices in different grades of
ECOPACK
®
packages, depending on their level of environmental compliance. ECOPACK
®
specifications, grade definitions and product status are available at: www.st.com.
ECOPACK
®
is an ST trademark.
Table 15. TO-220 mechanical data (type STD-ST Dual Gauge)
Dim.
mm
Min. Typ. Max.
A 4.40 4.60
b 0.61 0.88
b1 1.14 1.70
c 0.48 0.70
D 15.25 15.75
D1 1.27
E 10 10.40
e 2.40 2.70
e1 4.95 5.15
F 1.23 1.32
H1 6.20 6.60
J1 2.40 2.72
L13 14
L1 3.50 3.93
L20 16.40
L30 28.90
∅
P 3.75 3.85
Q 2.65 2.95