Datasheet
Characteristics LCP02-150B1
4/10 Doc ID 7275 Rev 8
Table 5. Parameters related to the positive suppressor
Symbol Parameter Test conditions Min. Max. Unit
I
Gp
Positive gate trigger current V
Gp/GND
= 60 V, measured at 50 Hz 5 mA
V
DGL+
Dynamic switching voltage Gp / Line
(1)
V
Gp/GND
= 60 V
V
10/700 µs
1.2/50 µs
2 kV
2 kV
R
P
= 25 Ω
R
P
= 25 Ω
I
PP
= 30 A
I
PP
= 30 A
8
35
1. The V
DGL
value is the difference between the peak line voltage during the surge and the programmed gate voltage.
Table 6. Parameters related to line/GND
Symbol Parameter Test conditions Min. Max. Unit
I
R
Reverse leakage current
T
j
= 25 °C
T
j
= 25 °C
V
LINE
= +120 V
V
LINE
= -120 V
V
Gp/LINE
= +1 V
V
Gn/LINE
= -1 V
5
5
µA
C
off
Capacitance LINE/GND V
R
= -3 V, F =1 MHz, V
Gp
= 60 V, V
Gn
= -60 V 60 pF
Table 7. Recommended gate capacitance
Symbol Component Min. Typ. Max. Unit
C
G
Gate decoupling capacitance 100 220 nF
Obsolete Product(s) - Obsolete Product(s)