Datasheet

L99MC6 Description
Doc ID 16523 Rev 2 15/32
The following combination must be used: channel 1 + 4, channel 2 + 5, channel 3 + 6
(Figure 6).
A V
S
voltage exceeding the low-side clamping voltage (V
DRN_CL1-6
) , while the high one of
the high-side drivers is turned on, may cause a destruction of the device.
Caution: In bridge mode using channels 2 and 5, the IN/PWM pin has to be grounded. Therefore
PWM mode on other channels is not possible.
Figure 6. Example of bridge configuration
2.6 LED mode
Open-load detection in off-state can be deactivated to avoid the turn on of the LEDs by the
current source (150 ยตA typ.) when the channel is switched-off.
Moreover, it is possible to select a high slew rate to support PWM operations with small duty
cycle (see Section 9.3.1: Channel configuration decoding).
Control
V
DD
5V
SPI
=
1
Out1
Out2
Out3
Out4
Out5
Out6
GND
IN/PWM
V
S
12V
M
GND
SCK
CSN
DO
DI
M