Datasheet

DocID15567 Rev 6 17/53
L99H01 Electrical specifications
52
Table 15. Cross current protection time
(1)
Item Symbol Parameter Test condition Min. Typ. Max. Unit
15.1 t
CCP0
Cross current protection time 250
(2)
ns
15.2 t
CCP1
Cross current protection time 250 500 750
15.3 t
CCP2
Cross current protection time 500 750 1000
15.4 t
CCP3
Cross current protection time 700 1000 1300
15.5 t
CCP4
Cross current protection time 950 1250 1570
15.6 t
CCP5
Cross current protection time 1160 1500 1880
15.7 t
CCP6
Cross current protection time 1360 1750 2180
15.8 t
CCP7
Cross current protection time 1560 2000 2480
1. Test conditions: V
CC
= 5 V, V
S
= 13.5 V
2. Not tested
Table 16. Drain source monitoring
Item Symbol Parameter Test condition Min. Typ. Max. Unit
16.1 V
SCd1
Drain - source threshold voltage 0.15 0.5 0.7 V
16.2 V
SCd2
Drain - source threshold voltage 0.45 1 1.25 V
16.3 V
SCd3
Drain - source threshold voltage 0.9 1.5 1.8 V
16.4 V
SCd4
Drain - source threshold voltage 1.4 2 2.35 V
16.5 t
SCd
Drain - source filtertime 6 µs
Table 17. Thermal sense interface (4.5 V < V
CC
<5.3V)
Item Symbol Parameter Min. Typ. Max. Unit
17.1 I
TS_bias
Output bias current 200 250 300 µA
17.2 V
th_TS
TS threshold voltage
V
TS
< V
CC
- 1 V
n = number of diodes
m = programmed level (0 to 7)
n * (0.31 + m * 0.03) V
Table 18. Current sense amplifier
(1)
Item Symbol Parameter Test condition Min. Typ. Max. Unit
DC parameters
18.1 V
ICM
Input voltage range –
common mode
-4
V
CP
-
8V
V
18.2 V
IOFF50
Input offset voltage Gain = 50 -11 -4 3 mV
18.3 V
IOFF20
Input offset voltage Gain = 20 -23 -8 7 mV
18.4 V
IOFF10
Input offset voltage Gain = 10 -30 -10 10 mV
18.5 V
IOFF-T50
/ΔT
Input offset voltage drift vs.
temperature
Gain = 50 -10
(2)
µV/°K