Datasheet

Electrical specifications L99H01
14/53 DocID15567 Rev 6
9.6 V
VS_UV
Undervoltage disable
low threshold
4.7 4.9 5.1 V
9.7 V
VS_UVH
Undervoltage threshold
hysteresis
0.2 0.3 0.4 V
9.8.1
I
S
V
S
DC supply current
V
S
=13V; V
CC
=5V;
Active mode; Outputs
floating
4.5 5.5 6.5 mA
9.8.2
V
S
= 6 V to 28 V;
V
CC
= 5.0 V; Active
mode; Outputs floating
2.5 18 mA
9.9 I
SL
V
S
quiescent supply
current
V
S
=13V; V
CC
=0V;
Standby mode;
T
Tes t
= -40°C, 25°C;
Outputs floating
A
9.10 I
CC
V
CC
DC supply current
V
S
=13V; V
CC
=5V;
active mode
1.5 1.8 2.5 mA
9.11 I
CC
V
CC
quiescent supply
current
V
CC
= 5 V; standby
mode
30 70 150 µA
9.12 I
CC
d
V
CC
d
supply current
V
S
= 13 V;
V
CC
=V
CC
d
=5V;
active mode
250 500 750 µA
Table 10. Undervoltage detection
Item Symbol Parameter Test condition Min. Typ. Max. Unit
10.1 V
POR OFF
Power-on reset threshold V
CC
increasing 2.2 2.55 2.8 V
10.2 V
POR ON
Power-on reset threshold V
CC
decreasing 2.0 2.25 2.6 V
10.3 V
POR hyst
Power-on reset
hysteresis
V
POR OFF
- V
POR ON
0.2 0.3 0.4 V
Table 11. Watchdog
Item Symbol Parameter Test condition Min. Typ. Max. Unit
11.1 T
WDTO
Watchdog time out 50 60 100 ms
Table 9. Supply (continued)
Item Symbol Parameter Test condition Min. Typ. Max. Unit