6 Application information
Note: C
I
is required for stability. For value given, capacitor must be solid tantalum. If aluminium
electrolytic are used, at least ten times value should be selected. C
O
is required if regulator
is located an appreciable distance from power supply filter. To improve transient response. If
large capacitors are used, a high current diode from input to output (1N4001 or similar)
should be introduced to protect the device from momentary input short circuit.
(*) Against potential latch-up problems.
Figure 4. Fixed output regulator
Figure 5. Split power supply (± 15 V - 1 A)