Datasheet
Application information: monitoring and protection L6924U
24/37 Doc ID 14716 Rev 2
When the voltage (and thus, the temperature), returns to the window range, the device re-
starts the charging process. Moreover, there is a hysteresis for both the upper and lower
thresholds, as shown in
Figure 18.
Note: T
BAT
= OK when the battery temperature is between 0 °C and 50 °C
When the TH pin voltage rises and exceeds the V
MINTH
= 50 % of V
REF
(900 mV typ), the
L6924U stops the charge, and indicates a fault by the status pins. The device re-starts to
Figure 17. Battery temperature control flow chart
Figure 18. Voltage window with hysteresis on TH
Figure 19. Pin connection
V
MI NTH
V
MAXTH
V
MI NTH_ HYS
V
MAXTH_ HYS
900mV
780mV
225mV
248mV
Volt age
Variation on TH pin
Charge disable
Charge enable