6.9 Overcurrent detection
The L6480 measures the load current of each half-bridge sensing the V
DS
voltage of all the
Power MOSFETs (Figure 12). When any of the V
DS
voltages rise over the programmed
threshold, the OCD flag in the STATUS register is forced low until the event expires and a
GetStatus command is sent to the device (Section 9.1.24 on page 59 and Section 9.2.20 on
page 71). The overcurrent event expires when all the Power MOSFET V
DS
voltages fall
below the programmed threshold.
The overcurrent threshold can be programmed by the OCD_TH register in one of 32
available values ranging from 31.25 mV to 1 V with steps of 31.25 mV (Table 18 on page 50
Section 9.1.17 on page 50).
Figure 12. Overcurrent detection-principle scheme
The overcurrent detection comparators are disabled, in order to avoid wrong voltage
measurements, in the following cases:
The respective half-bridge is in high impedance state (both MOSFETs forced off)
The respective half-bridge is commutating
The respective half-bridge is commutated and the programmed blanking time has not
yet elapsed
The respective gate is turned off.
It is possible to set if an overcurrent event causes the bridge turn-off or not through the
OC_SD bit in the CONFIG register.
When the power bridges are turned off by an overcurrent event, they cannot be turned on
until the OCD flag is released by a GetStatus command.