Datasheet
DocID023278 Rev 4 21/75
L6480 Functional description
75
Figure 4. Charge pump circuitry
6.4 Microstepping
The driver is able to divide the single step into up to 128 microsteps. Stepping mode can be
programmed by the STEP_SEL parameter in the STEP_MODE register (Table 20 on
page 50).
Step mode can be only changed when bridges are disabled. Every time the step mode is
changed, the electrical position (i.e. the point of microstepping sine wave that is generated)
is reset to the first microstep and the absolute position counter value (Section 6.5) becomes
meaningless.
Figure 5. Normal mode and microstepping (128 microsteps)
9
6
9
6
9
&3 ' '
9
&3
I
3803
WRKLJKVLGH
JDWHGULYHUV
9
6
9
&3
9
'
&
%227
&
)/<
'
'
9%227 &3
9''
7
7
&KDUJHSXPSRVFLOODWRU
$0Y
VWHS VWHSVWHS VWHS VWHS VWHS
5HVHW
SRVLWLRQ
VWHSVWHS VWHS VWHS
1RUPDOGULYLQJ 0LFURVWHSSLQJ
3+$6($FXUUHQW
3+$6(%FXUUHQW
3+$6($FXUUHQW
3+$6(%FXUUHQW
PLFURVWHSV
VWHSV
VWHSV
VWHSV
VWHSV
5HVHW
SRVLWLRQ
".W