The SW_MODE bit sets the external switch to act as HardStop interrupt or not:
The OC_SD bit sets whether an overcurrent event causes or not the bridges to turn off; the
OCD flag in the STATUS register is forced low anyway:
The POW_SR bits set the slew rate value of power bridge output:
0100
External crystal or resonator: 8
MHz
Crystal/resonator
driving
Crystal/resonator
driving
0101
External crystal or resonator:
16 MHz
Crystal/resonator
driving
Crystal/resonator
driving
0110
External crystal or resonator:
24 MHz
Crystal/resonator
driving
Crystal/resonator
driving
0111
External crystal or resonator:
32 MHz
Crystal/resonator
driving
Crystal/resonator
driving
1100
Ext clock source: 8 MHz
(Crystal/resonator driver
disabled)
Clock source
Supplies inverted
OSCIN signal
1101
Ext clock source: 16 MHz
(Crystal/resonator driver
disabled)
Clock source
Supplies inverted
OSCIN signal
1110
Ext clock source: 24 MHz
(Crystal/resonator driver
disabled)
Clock source
Supplies inverted
OSCIN signal
1111
Ext clock source: 32 MHz
(Crystal/resonator driver
disabled)
Clock source
Supplies inverted
OSCIN signal
Table 23. Oscillator management (continued)
EXT_C
LK
OSC_SEL[2..0] Clock source OSCIN OSCOUT
Table 24. External switch hard stop interrupt mode
SW_MODE Switch mode
0 HardStop interrupt
1 User disposal
Table 25. Overcurrent event
OC_SD Overcurrent event
1 Bridges shut down
0 Bridges do not shut down