Datasheet
Table Of Contents
- Table 1. Device summary
- 1 Block diagram
- 2 Electrical data
- 3 Electrical characteristics
- 4 Pin connection
- 5 Typical applications
- 6 Functional description
- 6.1 Device power-up
- 6.2 Logic I/O
- 6.3 Charge pump
- 6.4 Microstepping
- 6.5 Absolute position counter
- 6.6 Programmable speed profiles
- 6.7 Motor control commands
- 6.8 Internal oscillator and oscillator driver
- 6.9 Overcurrent detection
- 6.10 Undervoltage lockout (UVLO)
- 6.11 Thermal warning and thermal shutdown
- 6.12 Reset and standby
- 6.13 External switch (SW pin)
- 6.14 Programmable DMOS slew rate, deadtime and blanking time
- 6.15 Integrated analog-to-digital converter
- 6.16 Internal voltage regulator
- 6.17 BUSY\SYNC pin
- 6.18 FLAG pin
- 7 Phase current control
- 8 Serial interface
- 9 Programming manual
- 9.1 Registers and flags description
- Table 9. Register map
- 9.1.1 ABS_POS
- 9.1.2 EL_POS
- 9.1.3 MARK
- 9.1.4 SPEED
- 9.1.5 ACC
- 9.1.6 DEC
- 9.1.7 MAX_SPEED
- 9.1.8 MIN_SPEED
- 9.1.9 FS_SPD
- 9.1.10 KVAL_HOLD, KVAL_RUN, KVAL_ACC and KVAL_DEC
- 9.1.11 INT_SPEED
- 9.1.12 ST_SLP
- 9.1.13 FN_SLP_ACC
- 9.1.14 FN_SLP_DEC
- 9.1.15 K_THERM
- 9.1.16 ADC_OUT
- 9.1.17 OCD_TH
- 9.1.18 STALL_TH
- 9.1.19 STEP_MODE
- 9.1.20 ALARM_EN
- 9.1.21 CONFIG
- Table 22. CONFIG register
- Table 23. Oscillator management
- Table 24. External switch hard stop interrupt mode
- Table 25. Overcurrent event
- Table 26. Programmable power bridge output slew rate values
- Table 27. Motor supply voltage compensation enable
- Table 28. PWM frequency: integer division factor
- Table 29. PWM frequency: multiplication factor
- Table 30. Available PWM frequencies [kHz]: 8-MHz oscillator frequency
- Table 31. Available PWM frequencies [kHz]: 16-MHz oscillator frequency
- Table 32. Available PWM frequencies [kHz]: 24-MHz oscillator frequency
- Table 33. Available PWM frequencies [kHz]: 32-MHz oscillator frequency
- 9.1.22 STATUS
- 9.2 Application commands
- Table 37. Application commands
- 9.2.1 Command management
- 9.2.2 Nop
- 9.2.3 SetParam (PARAM, VALUE)
- 9.2.4 GetParam (PARAM)
- 9.2.5 Run (DIR, SPD)
- 9.2.6 StepClock (DIR)
- 9.2.7 Move (DIR, N_STEP)
- 9.2.8 GoTo (ABS_POS)
- 9.2.9 GoTo_DIR (DIR, ABS_POS)
- 9.2.10 GoUntil (ACT, DIR, SPD)
- 9.2.11 ReleaseSW (ACT, DIR)
- 9.2.12 GoHome
- 9.2.13 GoMark
- 9.2.14 ResetPos
- 9.2.15 ResetDevice
- 9.2.16 SoftStop
- 9.2.17 HardStop
- 9.2.18 SoftHiZ
- 9.2.19 HardHiZ
- 9.2.20 GetStatus
- 9.1 Registers and flags description
- 10 Package mechanical data
- 11 Revision history

L6470 Programming manual
Doc ID16737 Rev 5 41/70
9.1.1 ABS_POS
The ABS_POS register contains the current motor absolute position in agreement with the
selected step mode; the stored value unit is equal to the selected step mode (full, half,
quarter, etc.). The value is in 2's complement format and it ranges from -2
21
to +2
21
-1.
At power-on the register is initialized to “0” (HOME position).
Any attempt to write the register when the motor is running causes the command to be
ignored and the NOTPERF_CMD flag to rise (see Section 9.1.22).
9.1.2 EL_POS
The EL_POS register contains the current electrical position of the motor. The two MSbits
indicate the current step and the other bits indicate the current microstep (expressed in
step/128) within the step.
When the EL_POS register is written by the user, the new electrical position is instantly
imposed. When the EL_POS register is written, its value must be masked in order to match
with the step mode selected in the STEP_MODE register in order to avoid a wrong
microstep value generation (see Section 9.1.19); otherwise the resulting microstep
sequence is incorrect.
Any attempt to write the register when the motor is running causes the command to be
ignored and the NOTPERF_CMD flag to rise (see Section 9.1.22).
h18 CONFIG IC configuration 16 2E88
Internal oscillator, 2 MHz
OSCOUT clock, supply voltage
compensation disabled,
overcurrent shutdown enabled,
slew rate = 290 V/µs PWM
frequency = 15.6 kHz.
R, WH
h19 STATUS Status 16 XXXX
(2)
High impedance state,
UVLO/Reset flag set.
R
h1A RESERVED Reserved address
h1B RESERVED Reserved address
1. R: readable, WH: writable only when outputs are in high impedance, WS: writable only when motor is stopped, WR: always
writable.
2. According to startup conditions.
Table 9. Register map (continued)
Address
[Hex]
Register name Register function
Len.
[bit]
Reset
Hex
Reset
value
Remarks
(1)
Table 10. EL_POS register
Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
STEP MICROSTEP