Datasheet
Table Of Contents
- Table 1. Device summary
- 1 Block diagram
- 2 Electrical data
- 3 Electrical characteristics
- 4 Pin connection
- 5 Typical applications
- 6 Functional description
- 6.1 Device power-up
- 6.2 Logic I/O
- 6.3 Charge pump
- 6.4 Microstepping
- 6.5 Absolute position counter
- 6.6 Programmable speed profiles
- 6.7 Motor control commands
- 6.8 Internal oscillator and oscillator driver
- 6.9 Overcurrent detection
- 6.10 Undervoltage lockout (UVLO)
- 6.11 Thermal warning and thermal shutdown
- 6.12 Reset and standby
- 6.13 External switch (SW pin)
- 6.14 Programmable DMOS slew rate, deadtime and blanking time
- 6.15 Integrated analog-to-digital converter
- 6.16 Internal voltage regulator
- 6.17 BUSY\SYNC pin
- 6.18 FLAG pin
- 7 Phase current control
- 8 Serial interface
- 9 Programming manual
- 9.1 Registers and flags description
- Table 9. Register map
- 9.1.1 ABS_POS
- 9.1.2 EL_POS
- 9.1.3 MARK
- 9.1.4 SPEED
- 9.1.5 ACC
- 9.1.6 DEC
- 9.1.7 MAX_SPEED
- 9.1.8 MIN_SPEED
- 9.1.9 FS_SPD
- 9.1.10 KVAL_HOLD, KVAL_RUN, KVAL_ACC and KVAL_DEC
- 9.1.11 INT_SPEED
- 9.1.12 ST_SLP
- 9.1.13 FN_SLP_ACC
- 9.1.14 FN_SLP_DEC
- 9.1.15 K_THERM
- 9.1.16 ADC_OUT
- 9.1.17 OCD_TH
- 9.1.18 STALL_TH
- 9.1.19 STEP_MODE
- 9.1.20 ALARM_EN
- 9.1.21 CONFIG
- Table 22. CONFIG register
- Table 23. Oscillator management
- Table 24. External switch hard stop interrupt mode
- Table 25. Overcurrent event
- Table 26. Programmable power bridge output slew rate values
- Table 27. Motor supply voltage compensation enable
- Table 28. PWM frequency: integer division factor
- Table 29. PWM frequency: multiplication factor
- Table 30. Available PWM frequencies [kHz]: 8-MHz oscillator frequency
- Table 31. Available PWM frequencies [kHz]: 16-MHz oscillator frequency
- Table 32. Available PWM frequencies [kHz]: 24-MHz oscillator frequency
- Table 33. Available PWM frequencies [kHz]: 32-MHz oscillator frequency
- 9.1.22 STATUS
- 9.2 Application commands
- Table 37. Application commands
- 9.2.1 Command management
- 9.2.2 Nop
- 9.2.3 SetParam (PARAM, VALUE)
- 9.2.4 GetParam (PARAM)
- 9.2.5 Run (DIR, SPD)
- 9.2.6 StepClock (DIR)
- 9.2.7 Move (DIR, N_STEP)
- 9.2.8 GoTo (ABS_POS)
- 9.2.9 GoTo_DIR (DIR, ABS_POS)
- 9.2.10 GoUntil (ACT, DIR, SPD)
- 9.2.11 ReleaseSW (ACT, DIR)
- 9.2.12 GoHome
- 9.2.13 GoMark
- 9.2.14 ResetPos
- 9.2.15 ResetDevice
- 9.2.16 SoftStop
- 9.2.17 HardStop
- 9.2.18 SoftHiZ
- 9.2.19 HardHiZ
- 9.2.20 GetStatus
- 9.1 Registers and flags description
- 10 Package mechanical data
- 11 Revision history

Functional description L6470
32/70 Doc ID16737 Rev 5
Figure 14. Internal 3 V linear regulator
6.17 BUSY\SYNC pin
This pin is an open drain output which can be used as the busy flag or synchronization
signal according to the SYNC_EN bit value (STEP_MODE register).
6.17.1 BUSY operation mode
The pin works as busy signal when the SYNC_EN bit is set low (default condition). In this
mode the output is forced low while a constant speed, absolute positioning or motion
command is under execution. The BUSY
pin is released when the command has been
executed (target speed or target position reached). The STATUS register includes a BUSY
flag that is the BUSY pin mirror (see Section 9.1.22).
In the case of daisy chain configuration, BUSY pins of different ICs can be hard-wired to
save host controller GPIOs.
6.17.2 SYNC operation mode
The pin works as synchronization signal when the SYNC_EN bit is set high. In this mode a
step-clock signal is provided on the output according to a SYNC_SEL and STEP_SEL
parameter combination (see Section 9.1.19).
VREG VDD VSA VSB
AGNDDGND
V
DD
μC
IC
Vs
3V
VREG VDD VSA VSB
AGNDDGND
IC
3.3V
REG.
V
s
VBAT
Logig supplied by
INTERNAL voltage regulator
Logig supplied by
EXTERNAL voltage regulator