Datasheet
L6226Q Paralleled operation
Doc ID 14335 Rev 5 21/29
Figure 16. Parallel connection with lower overcurrent threshold
It is also possible to parallel the four half bridges to obtain a simple half bridge as shown in
Figure 17. In this configuration the, the over current threshold is equal to twice the minimum
threshold set by the resistors R
CLA
or R
CLB
in Figure 17. It is recommended to use
R
CLA
= R
CLB
.
The resulting half bridge has the following characteristics.
● Equivalent device: half bridge
● R
DS(on)
0.18 Ω typ. value @ T
J
= 25 °C
● 2.8 A max RMS load current
● 5.6 A max OCD threshold