Datasheet

15/23
L6206
To operate the device in parallel and maintain a lower over current threshold, Half Bridge 1 and the Half Bridge
2 of the Bridge A can be connected in parallel and the same done for the Bridge B as shown in Figure 14. In
this configuration, the peak current for each half bridge is still limited by the bond wires for the supply and sense
pins so the dissipation in the device will be reduced, but the peak current rating is not increased.
When connected in this configuration the over current detection circuit, senses the sum of the current in upper
devices connected in parallel. With the enables connected in parallel, an over current will turn of both bridges.
Since the circuit senses the total current in the upper devices, the over current threshold is equal to the threshold
set the resistor R
CLA
or R
CLB
in figure 14. R
CLA
sets the threshold when outputs OUT1
A
and OUT2
A
are high
and resistor R
CLB
sets the threshold when outputs OUT1
B
and OUT2
B
are high.
It is recommended to use R
CLA
= R
CLB
.
In this configuration, the resulting bridge has the following characteristics.
- Equivalent Device: FULL BRIDGE
- R
DS(ON)
0.15
Typ. Value @ T
J
= 25°C
- 2.8A max RMS Load Current
- 5.6A max OCD Threshold
Figure 14. Parallel connection with lower Overcurrent Threshold
C
P
C
BOOT
R
P
D
2
D
1
C
2
OUT1
A
LOAD
OCD
A
OCD
B
1
5
21
18
19
8
16
OUT2
A
GND
GND
GND
GND
PROGCL
A
OUT2
B
OUT1
B
VS
A
POWER
GROUND
SIGNAL
GROUND
+
-
VS
8-52V
DC
4
VS
B
VCP
VBOOT
C
1
SENSE
A
20
IN
A
IN1
A
IN2
A
2
6
7
9
EN
A
EN
B
C
EN
R
EN
EN
23
IN2
B
12
IN1
B
IN
B
11
14
24
17
3
15
22
SENSE
B
R
CLA
10
PROGCL
B
13
R
CLB
D02IN1361