Datasheet
DocID4340 Rev 18 7/38
L4931 Maximum ratings
3 Maximum ratings
Note: Absolute maximum ratings are those values beyond which damage to the device may occur.
Functional operation under these condition is not implied.
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
V
I
DC Input voltage 20 V
I
O
Output current Internally limited mA
P
D
Power dissipation Internally limited mW
T
STG
Storage temperature range -40 to 150 °C
T
OP
Operating junction temperature range -40 to 125 °C
Table 2. Thermal data
Symbol Parameter TO-92 DPAK SO-8 Unit
R
thJC
Thermal resistance junction-case 8 20 °C/W
R
thJA