Datasheet

3/9
IRF630 / FP
ELECTRICAL CHARACTERISTICS (CONTINUED)
SWITCHING ON
SWITCHING OFF
SOURCE DRAIN DIODE
Note: 1. Pulsed: Pulse duration = 300 µs, duty cycle 1.5 %.
2. Pulse width limited by safe operating area.
Symbol Parameter Test Conditions Min. Typ. Max. Unit
t
d(on)
Turn-on Delay Time
V
DD
= 100 V, I
D
= 4.5 A
R
G
= 4.7 V
GS
= 10 V
(see test circuit, Figure 3)
10 14 ns
t
r
Rise Time 15 20 ns
Q
g
Total Gate Charge
V
DD
= 160V, I
D
= 9 A,
V
GS
= 10V
31 45 nC
Q
gs
Gate-Source Charge 7.5 nC
Q
gd
Gate-Drain Charge 9 nC
Symbol Parameter Test Conditions Min. Typ. Max. Unit
t
r(Voff)
Off-voltage Rise Time
V
DD
= 160V, I
D
= 9 A,
R
G
=4.7Ω, V
GS
= 10V
(see test circuit, Figure 5)
12 17 ns
t
f
Fall Time 12 17 ns
t
c
Cross-over Time 25 35 ns
Symbol Parameter Test Conditions Min. Typ. Max. Unit
I
SD
Source-drain Current 9 A
I
SDM
(2)
Source-drain Current (pulsed) 36 A
V
SD
(1)
Forward On Voltage
I
SD
= 9 A, V
GS
= 0
1.5 V
t
rr
Reverse Recovery Time
I
SD
= 9 A, di/dt = 100A/µs
V
DD
= 50 V, T
j
= 150°C
(see test circuit, Figure 5)
170 ns
Q
rr
Reverse Recovery Charge 0.95 µC
I
RRM
Reverse Recovery Current 11 A
Safe Operating Area for TO-220FPSafe Operating Area for TO-220