Datasheet
HCF4094B
4/13
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are those values beyond which damage to the device may occur. Functional operation under these conditions is
not implied.
All voltage values are referred to V
SS
pin voltage.
(*) 500mW at 65
°C; derate to 300mW by 10mW/°Cfrom65°Cto85°C
RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Value Unit
V
DD
Supply Voltage
-0.5 to +22 V
V
I
DC Input Voltage -0.5 to V
DD
+0.5
V
I
I
DC Input Current
± 10 mA
P
D
Power Dissipation per Package 500 (*) mW
Power Dissipation per Output Transistor 100 mW
T
op
Operating Temperature
-55 to +125 °C
T
stg
Storage Temperature
-65 to +150 °C
Symbol Parameter Value Unit
V
DD
Supply Voltage
3to20 V
V
I
Input Voltage 0 to V
DD
V
T
op
Operating Temperature
-55 to 125 °C