Datasheet
Electrical characteristics L6563S
12/43 Doc ID 16116 Rev 4
Gv Voltage gain Open loop 60 80 dB
GB Gain-bandwidth product 1 MHz
I
COMP
Source current V
COMP
= 4 V, V
INV
= 2.4 V 2 4 mA
Sink current V
COMP
= 4 V, V
INV
= 2.6 V 2.5 4.5 mA
V
COMP
Upper clamp voltage I
SOURCE
= 0.5 mA 5.7 6.2 6.7
VBurst-mode voltage
(3)
2.3 2.4 2.5
Lower clamp voltage I
SINK
= 0.5 mA
(3)
2.1 2.25 2.4
Current sense comparator
I
CS
Input bias current V
CS
= 0 1 µA
t
LEB
Leading edge blanking 100 150 250 ns
td
(H-L)
Delay to output 100 200 300 ns
V
CSclamp
Current sense reference clamp
V
COMP
= Upper clamp,
V
MULT
=1 V V
VFF
= 1 V
1.0 1.08 1.16 V
Vcs
ofst
Current sense offset
V
MULT
= 0, V
VFF
= 3 V 40 70
mV
V
MULT
= 3 V, V
VFF
= 3 V 20
Boost inductor saturation detector
V
CS_th
Threshold on current sense
(3)
1.6 1.7 1.8 V
I
INV
E/A input pull-up current After V
CS
> V
CS_th
, before restarting 5 10 13 µA
PFC_OK functions
I
PFC_OK
Input bias current V
PFC_OK
= 0 to 2.6 V -0.1 -1 µA
V
PFC_OK_C
Clamp voltage I
PFC_OK
= 1 mA 9 9.5 V
V
PFC_OK_S
OVP threshold
(1)
voltage rising 2.435 2.5 2.565 V
V
PFC_OK_R
Restart threshold after OVP
(1)
voltage falling 2.34 2.4 2.46 V
V
PFC_OK_D
Disable threshold
(1)
voltage falling 0.12 0.35 V
V
PFC_OK_D
Disable threshold
(1)
voltage falling T
J
= 25 °C 0.17 0.23 0.29 V
V
PFC_OK_E
Enable threshold
(1)
voltage rising 0.15 0.38 V
V
PFC_OK_E
Enable threshold
(1)
voltage rising Tj = 25 °C 0.21 0.27 0.32 V
V
FFD
Feedback failure detection
threshold (V
INV
falling)
V
PFC_OK
> V
PFC_OK_S
1.61 1.66 1.71 mV
Zero current detector
V
ZCDH
Upper clamp voltage I
ZCD
= 2.5 mA 5.0 5.7 V
V
ZCDL
Lower clamp voltage I
ZCD
= - 2.5 mA -0.3 0 0.3 V
V
ZCDA
Arming voltage
(positive-going edge)
1.1 1.4 1.9 V
Table 4. Electrical characteristics (continued)
Symbol Parameter Test condition Min. Typ. Max. Unit