Datasheet
AN3065 Test results and significant waveforms
Doc ID 16279 Rev 2 19/33
In Figure 24 a startup tentative below the threshold is captured. As visible at startup the
RUN pin does not allow PFC startup.
In Figure 25 and 26 the waveforms of the circuit during operation of the brownout protection
are captured. In both cases the mains voltage was increased or decreased slowly. As visible
both at turn-on or turn-off there are no bouncing or starting attempts by the PFC converter.
Figure 24. EVL6563S-100W TM PFC startup
attempt at 80Vac, 60 Hz, full load
CH1: PFC output voltage
CH2: Vcc voltage (pin #14)
CH3: RUN (pin #10)
CH4: gate drive (pin #13)
Figure 25. EVL6563S-100W TM PFC: startup
with slow input voltage increasing,
full load
Figure 26. EVL6533S-100W TM PFC: turn-off
with slow input voltage decreasing,
full load
CH1: PFC output voltage
CH2: Vcc (pin #14)
CH3: RUN (pin #10)
CH4: Gate drive (pin #13)
CH1: PFC output voltage
CH2: Vcc (pin #14)
CH3: RUN (pin #10)
CH4: Gate drive (pin #13)