Datasheet

Test results and significant waveforms AN3065
10/33 Doc ID 16279 Rev 2
4 Test results and significant waveforms
4.1 Harmonic content measurement
One of the main purposes of a PFC pre-conditioner is the correction of input current
distortion, decreasing the harmonic contents below the limits of the relevant regulations.
Therefore, this demonstration board has been tested according to the European standard
EN61000-3-2 Class-D and Japanese standard JEITA-MITI Class-D, at full load at both the
nominal input voltage mains.
The circuit is able to reduce the harmonics well below the limits of both regulations from full
load down (measurements are shown in Figure 3 and 4) to light load. Please note that all
measures and waveforms have been done using a Pi-filter for filtering the noise coming from
the circuit, using a 20 mH common-mode choke and two 470NF-X2 filter capacitors.
Figure 3. EVL6563S-100W TM PFC:
compliance to EN61000-3-2
standard
Figure 4. EVL6563S-100W TM PFC:
compliance to JEITA-MITI standard
Vin = 230 Vac - 50 Hz
Pout = 100 W
THD = 2.31 %
PF = 0.982
Vin = 100 Vac - 50 Hz
Pout = 100 W
THD = 2.30 %
PF = 0.999
!-V






+DUPRQLF2UGHU>Q@
+DUPRQLF&XUUHQW>$@
0HDVXUHGYDOXH (1&ODVV'OLPLWV
!-V






+DUPRQLF2UGHU>Q@
+DUPRQLF&XUUHQW>$@
0HDVXUHGYDOXH -(,7$0,7,&ODVV'OLPLWV