Datasheet
AN3063 Test results and significant waveforms
Doc ID 16261 Rev 3 19/33
In Figure 24 a startup tentative below the threshold is captured. As visible, at startup the
RUN pin does not allow PFC startup.
In Figure 25 and 26 the waveforms of the circuit during operation of the brownout protection
are captured. In both cases the mains voltage was increased or decreased slowly. As
visible, both at turn-on or turn-off there are no bouncing or starting attempts by the PFC
converter.
Figure 24. EVL6563H-100W startup attempt at
80 Vac, 60 Hz, full load
CH1: PFC output voltage
CH2: Vcc voltage (pin #16)
CH3: RUN (pin #12)
CH4: gate drive (pin #15)
Figure 25. EVL6563H-100W startup with slow
input voltage increasing, full load
Figure 26. EVL6533H-100W turn-off with slow
input voltage decreasing, full load
CH1: PFC output voltage
CH2: Vcc (pin #16)
CH3: RUN (pin #12)
CH4: Gate drive (pin #15)
CH1: PFC output voltage
CH2: Vcc (pin #16)
CH3: RUN (pin #12)
CH4: Gate drive (pin #15)