Datasheet

L6562A Application examples and ideas
19/26
Figure 22. L6562A 80W TM PFC evaluation
board: compliance to EN61000-3-2
standard
Figure 23. L6562A 80W TM PFC evaluation
board: compliance to JEIDA-MITI
standard
Vin = 230 Vac - 50 Hz, Pout = 80 W
THD = 10.48 %, PF = 0.973
Vin = 100 Vac - 50 Hz, Pout = 80 W
THD = 3.18 %, PF = 0.997
0. 0001
0.001
0.01
0. 1
1
1 3 5 7 9 1113151719212325272931 333537 39
Harmonic Order (n)
Harmonic current (A)
Measurements @ 230Vac Ful l load EN61000-3-2 cl as s D li mit s
0.0001
0.001
0.01
0. 1
1
1 3 5 7 9 1113151719212325272931333537 39
Harmonic Order (n)
Harmoni c current (A)
Measurement s @ 100Vac Full load JEIDA-MITI class D limits
Figure 24. Figure 3 - L6562A 80W TM PFC
Evaluation board: Input Current
waveform @230V-50Hz – 80W load
Figure 25. Figure 4- L6562A 80W TM PFC
Evaluation board: Input Current
waveform @100V-50Hz – 80W load