Datasheet

Burst test AN2838
16/23 DocID15099 Rev 2
6 Burst test
The board has been tested against burst pulses, with good results. The tests have been
carried out using the following equipment and the procedures:
Surge generator: Schaffner NSG 200 E 7 NSG 224 A
Test types:
SYM = symmetric with respect to earth pole (pulse applied between line and
neutral)
ASYM = asymmetric (pulse applied between line and earth and between neutral
and earth)
Output load 700 mA.
Figure 26. Burst pulse and characteristics
Table 3. Burst test report table
Configuration
Amplitude
Polarity and
phase
Pulse type
Pulse frequency
Pulse number
(burst)
Pause
Pulse number
(burst)
Pause
Pulse number
(burst)
Pause
Pulse number
(burst)
Pause
SYM 2.5 kV + 90° III 1 Hz 10 15” 10 15” 10 15” 10 15”
10 15”
SYM 2.5 kV - 270° III 1 Hz 10 15” 10 15” 10 15” 10 15”
10 15”
ASYM 2.5 kV + 90° III 1 Hz 10 15” 10 15” 10 15” 10 15”
10 15”
ASYM 2.5 kV - 270° III 1 Hz 10 15” 10 15” 10 15” 10 15”
10 15”