Datasheet

Power bridges L6460
70/139 Doc ID 17713 Rev 1
3 32 -63.4 -77.3 219.4°
5 9 17 33 -70.7 -70.7 225°
34 -77.3 -63.4 230.6°
18 35 -83.1 -55.6 236.2°
36 -88.2 -47.1 241.9°
10 19 37 -92.4 -38.3 247.5°
38 -95.7 -29.0 253.1°
20 39 -98.1 -19.5 258.8°
40 -100 -9.8 264.4°
6 3 11 21 41 -100 HiZ 270°
42 -100 9.8 275.6°
22 43 -98.1 19.5 281.2°
44 -95.7 29.0 286.9°
12 23 45 -92.4 38.3 292.5°
46 -88.2 47.1 298.1°
24 47 -83.1 55.6 303.8°
48 -77.3 63.4 309.4°
7 4 13 25 49 -70.7 70.7 315°
50 -63.4 77.3 320.6°
26 51 -55.6 83.1 326.2°
52 -47.1 88.2 331.9°
14 27 53 -38.3 92.4 337.5°
54 -29.0 95.7 343.1°
28 55 -19.5 98.1 348.8°
56 -9.8 100 354.4°
8 4 15 29 57 HiZ 100 360°/0°
58 9.8 100 5.6°
30 59 19.5 98.1 11.2°
60 29.0 95.7 16.9°
16 31 61 38.3 92.4 22.5°
62 47.1 88.2 28.1°
Table 25. Internal sequencer (continued)
Control mode
Typical output
current (% of IMAX)
Resulting
electrical
angle
Half
step
Full step
(2 phases
on)
Full step
(1 phase
on)
1/4
step
1/8
step
1/16
step
Phase A
(sin)
Phase B
(cos)
Electrical
degrees