Datasheet
Electrical specifications L9826
10/19 Doc ID 7214 Rev 10
t
csdv
NCS = LOW to data at SDO
active
---100ns
t
sclch
CLK low before NCS low
Setup time CLK to NCS change
H/L
100 - - ns
t
hclcl
CLK change L/H after NCS =
low
-100--ns
t
scld
SDI input setup time
CLK change H/L after SDI data
valid
20 - - ns
t
hcld
SDI input hold time
SDI data hold after CLK change
H/L
- - 20 ns
t
sclcl
CLK low before NCS high - 150 - - ns
t
hclch
CLK high after NCS high - 150 - - ns
t
pchdz
NCS L/H to output data float - - - 100 ns
- NCS pulse filter time
Multiple of 8 CLK cycles inside
NCS period
----
Table 6. Electrical characteristics (continued)
Symbol Parameter Test condition Min. Typ. Max. Unit