4.3 OPERATING CONDITIONS
4.3.1 General operating conditions
Table 4.4 Operating conditions
Symbol
Parameter
Min.
Typ.
Max.
Unit
VDD_PADS
Regulator input voltage (VDD_PADS)
2,1
3,6
V
TOP
Operating temperature range
-40
85
°C
4.3.2 Electrostatic discharge (ESD)
Electrostatic discharges (a positive then a negative pulse separated by 1 second) are applied to the pins of each sample
according to each pin combination. The sample size depends on the number of supply pins in the device (3 parts × (n+1)
supply pins). This test conforms to the JESD22-A114/C101 standard.
Table 4.5 ESD absolute maximum ratings
Symbol
Ratings
Conditions
Class
Maximum value
Unit
VESD (HBM)
Electrostatic discharge voltage (Human
Body Model)
TA = +25 °C conforming
to JESD22-A114
2
±2000
V
VESD (CDM)
Electrostatic discharge voltage (Charge
Device Model) for non-RF pins
TA = +25 °C conforming
to JESD22-C101
II
±400
Electrostatic discharge voltage (Charge
Device Model) for RF pins
±225
MSL
Moisture sensitivity level
MSL3