Datasheet

BTA24, BTB24, BTA25, BTA26, BTB26, T25 Characteristics
3/12
Table 4. Electrical characteristics (T
j
= 25° C, unless otherwise specified),
standard (4 quadrants), BTB24...B, BTA25...B, BTA26...B, BTB26...B
Symbol Test Conditions Quadrant Value Unit
I
GT
(1)
V
D
= 12 V R
L
= 33 Ω
I - II - III
MAX.
50
mA
IV 100
V
GT
ALL MAX. 1.3 V
V
GD
V
D
= V
DRM
R
L
= 3.3 kΩ T
j
= 125° C ALL MIN. 0.2 V
I
H
(2)
)I
T
= 500 mA MAX. 80 mA
I
L
I
G
= 1.2 I
GT
I - III - IV
MAX.
70
mA
II 160
dV/dt
(2)
V
D
= 67 %V
DRM
gate open T
j
= 125° C MIN. 500 V/µs
(dV/dt)c
(2)
(dI/dt)c = 13.3 A/ms T
j
= 125° C MIN. 10 V/µs
1. minimum I
GT
is guaranted at 5% of I
GT
max.
2. for both polarities of A2 referenced to A1.
Table 5. Static characteristics
Symbol Test Conditions Value Unit
V
TM
(1)
I
TM
= 35 A t
p
= 380 µs T
j
= 25° C MAX. 1.55 V
V
t0
(1)
Threshold voltage T
j
= 125° C MAX. 0.85 V
R
d
(1)
Dynamic resistance T
j
= 125° C MAX. 16 mΩ
I
DRM
I
RRM
V
DRM
= V
RRM
T
j
= 25° C
MAX.
A
T
j
= 125° C 3 mA
1. for both polarities of A2 referenced to A1.
Table 6. Thermal resistance
Symbol Parameter Value Unit
R
th(j-c)
Junction to case (AC)
TOP 3 0.6
° C/W
D
2
PAK / TO-220AB 0.8
RD91 Insulated / TOP3 Insulated 0.9
TO-220AB Insulated 1.7
R
th(j-a)
Junction to ambient
(1)
S = 1 cm
²
D
2
PA K 4 5
° C/WTOP3 / TOP3 Insulated 50
TO-220AB / TO-220AB Insulated 60
1. S = Copper surface under tab.