Datasheet

BTA40 and BTA/BTB41 Series
2/6
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified)
STATIC CHARACTERISTICS
Note 1: minimum IGT is guaranted at 5% of IGT max.
Note 2: for both polarities of A2 referenced to A1
THERMAL RESISTANCES
PRODUCT SELECTOR
BTB: Non insulated TOP3 package
Symbol Test Conditions Quadrant Value Unit
I
GT
(1)
V
D
=12V R
L
=33
I - II - III
IV
MAX.
50
100
mA
V
GT
ALL MAX. 1.3 V
V
GD
V
D
=V
DRM
R
L
= 3.3 k
Tj = 125°C
ALL MIN.
0.2 V
I
H
(2)
I
T
= 500 mA
MAX. 80 mA
I
L
I
G
= 1.2 I
GT
I - III - IV MAX. 70 mA
II 160
dV/dt (2) V
D
=67%V
DRM
gate open Tj = 125°C
MIN. 500 V/µs
(dV/dt)c (2) (dI/dt)c = 20 A/ms Tj = 125°C MIN. 10 V/µs
Symbol Test Conditions Value Unit
V
TM
(2) I
TM
=60A tp=380µs
Tj = 25°C MAX. 1.55 V
V
to
(2)
Threshold voltage Tj = 125°C MAX. 0.85 V
R
d
(2)
Dynamic resistance Tj = 125°C MAX. 10 m
I
DRM
I
RRM
V
DRM
=V
RRM
Tj = 25°C
MAX.
5 µA
Tj = 125°C5mA
Symbol Parameter Value Unit
R
th(j-c)
Junction to case (AC) RD91 (Insulated)
TOP3
0.9
°C/W
TOP3 Insulated 1.2
R
th(j-a)
Junction to ambient TOP3
50
°C/W
TOP3 Insulated
Part Number
Voltage (xxx)
Sensitivity Type
Package
600 V 800 V
BTA40-xxxB X X 50 mA Standard RD91
BTA/BTB41-xxxB X X 50 mA Standard TOP3