Datasheet
1/6
BTA40 and BTA/BTB41 Series
STANDARD 40A TRIACS
September 2000 - Ed: 3
MAIN FEATURES:
DESCRIPTION
Available in high power packages, the BTA/
BTB40-41 series is suitable for general purpose
AC power switching. They can be used as an ON/
OFF function in applications such as static relays,
heating regulation, water heaters, induction motor
starting circuits, welding equipment... or for phase
control operation in high power motor speed con-
trollers, soft start circuits...
Thanks to their clip assembly technique, they
provide a superior performance in surge current
handling capabilities.
By using an internal ceramic pad, the BTA series
provides voltage insulated tab (rated at 2500 V
RMS) complying with UL standards (File ref.:
E81734).
Symbol Value Unit
I
T(RMS)
40 A
V
DRM
/V
RRM
600 and 800 V
I
GT (Q
1
)
50 mA
ABSOLUTE MAXIMUM RATINGS
Symbol Parameter Value Unit
I
T(RMS)
RMS on-state current
(full sine wave)
RD91
Tc = 80°C
40
A
TOP3
TOP3 Ins. Tc = 70°C
I
TSM
Non repetitive surge peak on-state
current (full cycle, Tj initial = 25°C)
F = 60 Hz t = 16.7 ms 420 A
F = 50 Hz t = 20 ms 400
I
tI
t Value for fusing
tp = 10 ms 1120
A
s
dI/dt
Critical rate of rise of on-state current
I
G
=2xI
GT
,tr≤100 ns
F = 120 Hz Tj = 125°C50 A/µs
V
DSM
/V
RSM
Non repetitive surge peak off-state
voltage
tp = 10 ms Tj = 25°C
V
DRM
/V
RRM
+ 100
V
I
GM
Peak gate current tp = 20 µs Tj = 125°C8 A
P
G(AV)
Average gate power dissipation Tj = 125°C1 W
T
stg
T
j
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
°C
G
A2
A1
A1
A2
G
A2
A2
A1
G
RD91
(BTA40)
A1
A2
G
TOP3
(BTB41)
TOP3 Insulated
(BTA41)