Data Sheet
BlueNRG-M2SA
Rev 0.1 P a g e | 9
32
4.4 Current consumption
Characteristics measured over recommended operating conditions unless otherwise
specified. Typical value are referred to T
A
= 25 °C, V
in
= 3.0 V
Current consumption values has been taken using the “BlueNRG current consumption estimation tool”,
configured to match the BLUENRG-M2SA configuration.
The tool is available on ST.com at: http://www.st.com/en/embedded-software/stsw-bnrg001.html
Reported values have been taken configuring the tool as shown in the Figure 4.
Figure 4: Configuration of the “BlueNRG Current Consumption Estimation Tool”
Symbol
Parameter
Test conditions
Typ.
Unit
IDD
Supply current
Reset
5
nA
Standby
500
nA
Sleep mode
0.9
µA
Active Mode
1.9
mA
RX
7.7
mA
TX: +8 dBm (programmed)
17
mA
TX: 0 dBm 11 mA