Datasheet

Datasheet parameters over the temperature range B5973D
8/44 DocID14117 Rev 4
4 Datasheet parameters over the temperature range
The 100% of the population in the production flow is tested at three different ambient
temperatures (-40 C; +25 C, +125 C) to guarantee the datasheet parameters inside the
junction temperature range (-40 C; +125 C).
The device operation is so guaranteed when the junction temperature is inside the
(-40 C; +150 C) temperature range. The designer can estimate the silicon temperature
increase respect to the ambient temperature evaluating the internal power losses generated
during the device operation (please refer to Section 2.2: Thermal data on page 5).
However the embedded thermal protection disables the switching activity to protect the
device in case the junction temperature reaches the T
SHTDWN
(+150 C ± 10 C)
temperature.
All the datasheet parameters can be guaranteed to a maximum junction temperature of
+125 C to avoid triggering the thermal shutdown protection during the testing phase
because of self heating.