Datasheet

74VHC132
3/11
Table 6: DC Specifications
Table 7: AC Electrical Characteristics (Input t
r
= t
f
= 3ns)
(*) Voltage range is 3.3V ± 0.3V
(**) Voltage range is 5.0V ±
0.5V
Symbol Parameter
Test Condition Value
Unit
V
CC
(V)
T
A
= 25°C
-40 to 85°C -55 to 125°C
Min. Typ. Max. Min. Max. Min. Max.
V
t+
High Level
Threshold Voltage
3.0 2.2 2.2 2.2
V4.5 3.15 3.15 3.15
5.5 3.85 3.85 3.85
V
t-
Low Level
Threshold Voltage
3.0 0.9 0.9 0.9
V4.5 1.35 1.35 1.35
5.5 1.65 1.65 1.65
V
h
Hysteresis Voltage 3.0 0.3 1.2 0.3 1.2 0.3 1.2
V4.5 0.4 1.4 0.4 1.4 0.4 1.4
5.5 0.5 1.6 0.5 1.6 0.5 1.6
V
OH
High Level Output
Voltage
2.0
I
O
=-50 µA
1.9 2.0 1.9 1.9
V
3.0
I
O
=-50 µA
2.9 3.0 2.9 2.9
4.5
I
O
=-50 µA
4.4 4.5 4.4 4.4
3.0
I
O
=-4 mA
2.58 2.48 2.4
4.5
I
O
=-8 mA
3.94 3.8 3.7
V
OL
Low Level Output
Voltage
2.0
I
O
=50 µA
0.0 0.1 0.1 0.1
V
3.0
I
O
=50 µA
0.0 0.1 0.1 0.1
4.5
I
O
=50 µA
0.0 0.1 0.1 0.1
3.0
I
O
=4 mA
0.36 0.44 0.55
4.5
I
O
=8 mA
0.36 0.44 0.55
I
I
Input Leakage
Current
0 to
5.5
V
I
= 5.5V or GND
± 0.1 ± 1 ± 1 µA
I
CC
Quiescent Supply
Current
5.5
V
I
= V
CC
or GND
22020µA
Symbol Parameter
Test Condition Value
Unit
V
CC
(V)
C
L
(pF)
T
A
= 25°C
-40 to 85°C -55 to 125°C
Min. Typ. Max. Min. Max. Min. Max.
t
PLH
t
PHL
Propagation Delay
Time
3.3
(*)
15 5.6 11.9 1.0 14.0 1.0 14.0
ns
3.3
(*)
50 7.6 15.4 1.0 17.5 1.0 17.5
5.0
(**)
15 3.9 7.7 1.0 9.0 1.0 9.0
5.0
(**)
50 5.3 9.7 1.0 11.0 1.0 11.0